Maintenance of Gongming automatic induction door - Haifeng has professionalsMaintenance and precautions of automatic induction door
When the responsive door breaks down, we should calm down and do the following work.
(1) Clean the oil and dust in the box;
(2) Check the wear condition of each part of the automatic sensing door;
(3) Check the support deviation, screw tightness and belt tightness of the automatic door;
(4) Check the controller motor output, door opening and closing width, speed, braking and other conditions;
(5) Check the voltage parameter to ensure the normal maintenance of damaged components
Maintenance method of automatic induction door
First: the mechanical transmission part shall be coated with gear oil, and the dusty part shall be cleaned and re coated with lubricating oil.
Second: stainless steel shell should not be cleaned with corrosive detergent, otherwise it is easy to appear rust spots, affecting the appearance.
Third: if the door operator does not move and there is a buzz during use, please close the switch immediately
Check whether the automatic door is jammed with foreign matters, and recover the power supply after troubleshooting!
Fourth: if the door is always open or closed, turn off the power immediately and check the sensor and phase in time
Close the circuit and replace the damaged parts in time to avoid damaging the motor and causing greater loss!
Fifth: if the glass is broken, please turn off the motor to avoid uneven weight
Damage to motor!
Sixth: when not in use for a long time, please cut off the power supply to avoid the motor being damaged by lightning!