Site: Home > News > Industry News > Details

How to deal with the failure of Foton [automatic induction door] in operation / repair of Foton induction door

Time: 2021-04-10 View: 1328

How to deal with the failure of Foton [automatic induction door] in operation / repair of Foton induction door


How to deal with the failure of Foton [automatic induction door] in operation

Shenzhen Haifeng automatic induction door maintenance equipment and debugging is the key to accuracy, that is, the straightness and levelness of the guide rail, parallelism and vertical straight line form the two hanging point door body and guide rail, greatly reducing the static side swing door body.


repair of Foton induction door

There are many kinds of faults in the operation of Haifeng automatic induction door, among which the opening fault is the most common. The opening faults of the automatic induction door include: the automatic door cannot be opened, the automatic door cannot be closed, the automatic door opens fast or slowly, the automatic door opens repeatedly and so on.



The automatic induction door can´t be opened



1. Set the door closing switch to remote control



2. If the controller fails, please check whether the sensor signal is normal. If not, please contact the maintenance department as soon as possible.



3. The door leaf can not operate normally due to the belt falling off.



4. Loose wire joint (short circuit).

5. The controller is burnt out and needs to be replaced.



6. If the motor fails, it may overheat and return to normal operation after cooling; if the motor is damaged, please replace it.



7. Foreign body stuck on the door leaf.



8. Abnormal voltage. Try opening it again.



The opening speed of automatic induction door is fast or slow



1. The setting speed of the controller is too high or too low.



2. The belt and automatic door pulley are worn and deformed



3. The gear box of the motor is worn and cannot be meshed tightly.



4. Belt aging



If the automatic induction door fails, you must find a professional maintenance company in time. The maintenance of automatic door needs certain professional knowledge, and the general users have no maintenance ability, which will cause greater losses.