In this issue, I will mainly share with you the precautions for the operation and maintenance of crystal roller shutter doors. Let´s have a look!
1. When operating the crystal rolling shutter door, the staff must operate at the position where the rolling shutter door body can be seen visually, otherwise they will suffer losses in case of sudden accidents
2. During the operation of the rolling gate machine, the sliding, transmission and other parts shall be inspected regularly at least twice a year, and the lubricating oil shall be filled in time as required to ensure the normal use of the crystal rolling gate
3. When the crystal rolling shutter door is electrically controlled, the opening and closing direction must be opposite to the indication of the switch. When the power supply is newly connected for test run or the phase line is changed with other input power supplies, the door curtain should be manually operated to the height of 1 / 2 of the door opening. After the power supply is connected, the rolling shutter door can be opened and closed for test operation. It can be used normally after it reaches the indication, otherwise the rolling shutter door will be rolled back or damaged due to the limiter, which will cause unequal losses
4. The crystal rolling shutter and door rolling machine shall avoid contact with the solution of acid and alkaline substances to prevent the surface of the door curtain from corrosion
The above is all the content shared by Xiaobian. I hope it will be helpful to you. If you want to know more about crystal roller shutter door, please contact us or pay attention to our official website - Shenzhen Haifeng door factory