Nanshan District automatic door controller wholesale replacement / factory automatic door control system maintenance price

Time: 2020-04-11 View: 1768
Nanshan District automatic door controller wholesale replacement / factory automatic door control system maintenance price



When the automatic door is in use, there will be problems such as the automatic door is stuck and the control is not sensitive. What are the performance and precautions of the automatic door controller? Haifeng gives you a brief introduction:


Automatic door controller performance


1. Power supply: 180-240v / 50-60Hz


2. Maximum load power: 1200W (resistance)


3. Power consumption of the controller itself: ≤ 5W


4. Control mode:


Manual control: chassis panel control and external button control


Wireless remote control: the frequency is 315MHz / 433MHz, and the coding encryption control is adopted


Signal conversion time: 1-0.5 seconds


Automatic stop: it is equipped with limit stop, 35S, 70s, 110s, 145s and 180s automatic delay stop (factory setting is 145s).


5. Alarm control:


Output interface: the alarm probe can provide 12V or 15V DC power supply


Input interface: alarm output is relay independent normally open contact


Alarm probe: infrared thermoluminescence, photoelectric, acoustic vibration, Doppler radar detection, electromagnetic induction and other types can be used. When the door body is opened and closed, the alarm function is released automatically. The monitoring distance of the probe shall not be less than 6-7m.


6. Other function interfaces: it can be connected with electronic display screen, perpetual calendar display screen, alarm light, door body sound, etc.


7. Acousto-optic display: the controller displays the following states:


Digital display: when the controller is powered on, it is in standby mode.


When the alarm function is enabled, the status changes from "-" to "day"


Display "H" when opening the door, "e" when closing the door, "" - "when shutting down".


Sound prompt: there is low frequency sound when opening or closing the door, and high frequency sound when alarming


8. Environmental conditions:


Temperature: - 10-45 ℃


Relative humidity: ≤ 85%


No corrosive gas and electromagnetic interference


Precautions for automatic door controller


1. The performance of the alarm function depends on the performance of the alarm probe. The user shall select the alarm probe according to the actual needs of the alarm. The controller is equipped with a heat release alarm probe at the factory. If the alarm function is not used, the detector will not work.


2. The type of alarm probe output signal interface is relay output interface, and the power supply voltage is DC 12-15v, otherwise the controller cannot directly supply power. The power consumption of the probe shall be ≤ 100mA. According to the field situation, multiple probes can be used (generally 1-2 are suitable), and parallel connection mode can be used when multiple probes are used. Investigation. Other heat sources or direct light shall be avoided, and rain cover shall be added on it.


3. The delay automatic shutdown function can be set according to the user´s door travel, which is about 145 seconds in the factory.


4. When it is found that the opening and closing directions are opposite, adjust the "V" and "W" terminal wiring of the controller. Similarly, when the direction indicated on the stop display is opposite to the actual direction, adjust the wiring in the same way.


5. In case of controller failure, professional personnel shall be responsible for maintenance or contact with suppliers and manufacturers for maintenance. In order to avoid failure expansion affecting use.


6. The control personnel shall keep clean and avoid contact with water or other harmful substances. Do not use organic solvent to clean the shell.


7. Generally, the number of switch cores shall not be less than 8 wires (if there are 7 wires before, the wiring is unreasonable), and there shall be no joint in the middle of the door body cable.


8. The remote transmitter shell shall be kept in good condition to prevent extrusion, vibration, falling and water. Pay attention to check the battery voltage and replace it in time if necessary. When the remote control is too close, the battery should be replaced. The battery model is kc12v-23a. The remote controller shall avoid the electromagnetic interference source as far as possible.


9. The remote control is encrypted according to the password and cannot be interchanged. When the user needs to change, the manufacturer can change the password as needed.